Outdoor and indoor resistance thermometer for ambient temperature measurement

Type series GA8100

  • EX
  • SIL2
Outdoor and indoor resistance thermometer for ambient temperature measurement - GA8100

Features

  • For ambient temperature measuring
  • Sturdy design: with die-cast aluminium case or with stainless steel field housing
  • Measuring resistor 1 x Pt 100, 3- wire technology, class A
  • Media temperature -40…80°C
  • Fast response

Options

  • Explosion protection
  • Classification per SIL2
  • Transmitter can be integrated
  • Temperature switch can be integrated
  • Protection sleeve against direct solar radiation and draught

Technical Data

Constructional design / case
Design sturdy die-cast aluminium case with mounting plate and separate earth terminal
Dimensions 80 x 75 x 57 mm
Degree of protection IP 66 per DIN EN 60529
Elec. connection M20 x 1,5 cable gland for cable Ø 5 - 9, material MS-nickel plated
M20 x 1,5 cable gland Skintop blue for cablel Ø 5-9, material PA
Alternative constructional design / case
Design stainless steel field housing for wall mounting or for pipe and frame mounting
Dimensions diameter: 60 mm,
height: 51 mm
Degree of protection IP 66 per DIN EN 60529
Elec. connection circular connector M12 x 1 (4-pin)
M12 x 1 cable gland for cable Ø 3-6,5, Material MS-nickel plated
Socket ceramic Ø 42 mm mounted on mounting plate
Temperature sensor
Sensor (U1) Ø 6 x 50 mm, material: stainless steel mat.-no. 1.4404 (316L)
Data sheet T4-044 Rev. 1G4
Measuring resistor 1 x Pt 100 in 3-wire technology, class A per DIN EN 60751
Accuracy
   
Measuring resistor Pt 100 per DIN EN 60751, class A
Temperature ranges
Media: -40…80°C
Storage: -40…80°C
Transmitter /temperature switch
Integration Transmitter for head mounting, Type series PA210., 4…20 mA, programmable
  Transmitter for head mounting, Type series PA220., electrically isolated, classification per SIL 2
  Transmitter for head mounting, Type series PA230., electrically isolated, classification per SIL 2, HART
   
Suitable Pt 100 transmitter or temperature switches (without Ex) can be mounted in cases for wall mounting.
Tests and certificates
See documents
Type series
GA8100, GA8101

Documents

Name
Description
EN
DE
  • T4-044

    Data Sheet

  • BA_069

    Operating Instruction

  • XA_001

    Ex Instructions

  • HE_087

    Manufacturer Declaration - SIL2

  • KE_011

    Declaration of Conformity