With screw-in thread HYGIENIC, hygienic sealing, no elastomer

Type series DE2130

With screw-in thread HYGIENIC, hygienic sealing, no elastomer - DE2130

Features

  • Flush-mounted separating diaphragm of stainless steel, laser welded
  • Hygienic sealing (no elastomer)
  • Fast and easy mounting
  • The measuring system can be positioned as required by means of the rotary screwed plug
  • Minimum mounting torque error/no torsion
  • System fillings for different applications
  • Measuring device connection: directly screwed, with capillary

Options

  • Material certificate acc. to EN 10204-3.1
  • Electropolishing (wetted parts)
  • Hygienic design with advanced surface quality
  • Special material upon request

Technical Data

Constructional design / case
Basic body: Volume reduced diaphragm base
Material: stainless steel mat.-no. 1.4404/1.4435 (316L)
Diaphragm: Flat diaphragm
Material wetted parts: Diaphragm: Stainless steel mat.-no. 1.4435 (316L)
Further materials upon request
  Basic body: Stainless steel mat.-no. 1.4404/1.4435 (316L)
Process connection
Design: G 1 A adjustable, metal-to-metal joint. Due to the rotary screw-in design no tor-sional forces are produced that could damage the sealing surface.
Tightening torque/Nominal pressure: 20 Nm, max. nominal pressure 10 bar
50 Nm, max. nominal pressure 50 bar
Mounting torque error
At a tightening torque of 20 Nm: 1 mbar
Measuring device connection
See order details.
Material stainless steel mat.-no. 1.4301 (304)
System filling
See order details; further fillings upon request.
Further details about pressure transmission fluids see general technical information TA_038.
Hygienic design
The surface roughness of the wetted parts made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3.
In case of choosing the additional feature HY, we guarantee the following surface roughness values:
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm
Further versions of hygienic design upon request.
Temperature error
In order to optimise the system we provide a detailed error calculation upon request .
Weight
Diaphragm seal and screwed plug approx. 0.3 kg
Further information about diaphragm seals see general technical information TA_031.
Flame arrester MF21xx for connection of measuring devices to zone 0 see data sheet D6-025.
Type series
DE2130

Documents

Name
Description
EN
DE
  • D5-024-7

    Data Sheet

  • TA_038

    Technical Information - Pressure Transmission Fluids

Productrequest