Pressure transmitter PASCAL CV with threaded connection

Type series CV3100

  • EX
  • SIL2
  • HART
  • PROFIBUS
Pressure transmitter PASCAL CV with threaded connection - CV3100

Features

  • Modular pressure transmitter with internal or flush mounted diaphragm.
  • Output signal: 4…20 mA, HART® protocol (rev. 6), option, PROFIBUS PA, option
  • Function modules: Multifunctional display with 5-segment digital display and bar graph, switching module with 2 floating channels, maximum 0.5 A switching current, electrically isolated at all sides, without additional auxiliary power
  • Function module replacement on site without recalibration "plug and measure"
  • Limits of measuring range 0...80 mbar to 0...400 bar
  • Accuracy ≤ 0,15 %
  • Turndown 5:1
  • Degree of proctection IP 66, piezoresistive measuring cell directly aerated

Options

  • Explosion protection for gases and dust
  • Certificate of measuring equipment for Russian Federation
  • Material certificate as per EN 10204-3.1
  • Calibration certificate as per EN 10204-3.1
  • Classification per SIL2
  • Degree of protection IP 69K
  • EAC declaration (upon request)

Technical Data

Measuring ranges
Detailed information see data sheet.
Constructional design / case
Design: Two-chamber case design with screw
cap.
  Minimum case volume, excellent moisture
and condensate protection
Material: Stainless steel mat.-no. 1.4301 (304)
Degree of protection per EN 60529: IP 66 per EN 60529
  optional: IP 69K
Climatic
category per
EN 60721 3-4:
4K4H
Pressure compensation: PTFE filter system
Window: Non splintering plastic: Makrolon
El. connection: Screw terminal 1 mm²
Cable gland: Cable gland M16, material: PA
  Circular connector M12
  (Further cable glands upon request.)
Weight: standard device with G1/2 without function modules approx. 0.65 kg
Process connection
Variants / material: See order code
Material wetted parts
Sensor: Piezoresistive Thin film
Sensor diaphragm: 1.4404/1.4435 (316L) 1.4542 (630)
Socket: 1.4404/1.4435 (316L) 1.4301/1.4404 (304/316L)
Gasket: EPDM-FDA listed --
Measuring system
Sensor: Piezoresistive Thin film
Sensor filling: Synthetic oil, free of silicone FD1, FDA listed without
Accuracy
Limit point setting: per DIN 16086
Reference conditions: per EN 60770-1
Linearity errors: ≤ 0.15 % of span
TD 5:1 no modification
Hysteresis: ≤ 0.05 % of nominal range
Repeatability: ≤ 0.05 % of nominal range
Calibration position: Vertical mounting position
Influence of mounting position: ≤ 3,5 mbar
Long-term drift (EN 60770-1): ≤ 0.1 % / year of nominal range
Temperature effect: Lower range value / upper range value
  Range 0…60 °C: ± 0.15 % / 10K of nominal range
  Range < 0 °C, > 60 °C: ± 0.2 % / 10K of nominal range
Output
General: Delay time: approx. 160 ms
  Measuring cycle: 6 measurements / second
  Measuring range
setting:
Turndown 5:1
Basic module: 4…20 mA Signal: 4…20 mA, 2-wire
  Current range: 3,8…20,8 mA
  Current limitation: approx. 22 mA
  Alarm state: < 3.6 mA, optional > 21 mA
  Damping: 0…120 seconds
  Load RB: RB ≤ (UV-12V DC)/0,022A [Ohm]
UV = supply voltage
Basic module: PROFIBUS PA Signal: digital per IEC 61158-2
  Protocol: EN 50170-PROFIBUS PA, Profile 3.0
  Sensor address: 0…126 (126 = factory setting)
  Power consumption: constantly 11 mA
  Fault current IFDE : 2 mA
  Damping: 0…300 seconds
  Parameterization: SIMATIC PDM
Supply voltage
Basic module: 4…20 mA PROFIBUS PA
Standard design:    
Functional range: 12…40 V DC 9…32 V DC
Ex-design:    
Functional range: 12…30 V DC 9...17.5 V DC
Temperature ranges
Ambient: -20…85 °C
Media: -20…90 °C
Storage: -40…85 °C
Note safety values as per examination certificate!
Tests and certificates
See documents
Type series
CV3100, CV3101

Documents

Name
Description
EN
DE
  • D4-017-1

    Data Sheet

  • BA_028

    Operating Instruction - Basic Module

  • BA_029

    Operating Instruction - Switching Module

  • BA_030

    Operating Instruction - Display Module

  • BA_031

    Operating Instruction - Display-Switching Module

  • BA_043

    Operating Instruction - PROFIBUS PA

  • BA_044

    Operating Instruction - PROFIBUS PA without Display

  • BA_045

    Operating Instruction - Changing the Module

  • BA_055

    Operating Instruction - HART

  • BA_081

    Operating Instruction - Display and HART

  • XA_015

    Ex Instructions

  • ZER_013

    Certificate - ATEX

  • ZER_041

    Certificate - HART

  • ZER_042

    Certificate - PROFIBUS PA

  • ZER_044

    Certificate - SIL2

  • HE_075

    Manufacturer Declaration - SIL2

  • KE_028

    Declaration of Conformity

  • Software

    PASCAL CV HART (DD/EDD) for Simatic PDM V6.0 SP5, V8.1 and V9.x

  • Software

    PASCAL CV Profibus PA (DD/EDD) for Simatic PDM V6.0 SP5

  • Software

    PASCAL CV HART (DD/EDD) for Emerson AMS V6.1 and V8.1

  • Software

    PASCAL CV HART (DD/EDD) für Emerson Handheld Communicator 375/475

Productrequest