Pressure transmitter/ switch PASCAL CS with threaded connection

Type series CS2100

Pressure transmitter/ switch PASCAL CS with threaded connection - CS2100

Features

  • Multifunctional pressure transmitter/pressure switch
  • Degree of protection IP 65
  • 4 digit LED display, can be mirror-imaged by 180°
  • Indication module rotatable by 300°
  • Measuring ranges: 0…100 mbar to 0…400 bar rel., 0…1 bar to 0…6 bar abs.
  • Output signal 4...20 mA, 2-wire technology
  • Accuracy ≤ 0,2 %
  • Easy to program locally (as per VDMA standard)
  • Galvanic isolation between transmitter and switching outputs
  • Various process connections

Options

  • Certificate of measuring equipment for Russian Federation
  • Material certificate as per EN 10204-3.1
  • Calibration certificate as per EN 10204-3.1
  • 2 floating contacts
  • Switching contacts with high switching current (1A)
  • Electrical connection rotatable by 300°
  • Degree of protection IP 67
  • EAC declaration (upon request)

Technical Data

Constructional design / case
Design: Sturdy case design
  Fully encapsulated electronics unit
Material: Stainless steel mat.-no. 1.4301 (304)
Indication module: macrolon
Degree of protection: - IP 65 per EN 60529
- Optional IP 67 per EN 60529
Pressure compensation: Aeration via sintered filter
Electrical connection: - circular connector M12, 4 pin
- circular connector M12, 8 pin (necessary for devices with switching contacts)
  Incl. sealing ring to ensure case is completely sealed
Climatic category: DIN EN 60721 3-4, 4K4H
Process connection
Design: See order details
Material wetted parts
Sensor: Piezoresistive Thin film
Sensor diaphragm: 1.4404/1.4435 (316L) 1.4542 (630)
Socket: 1.4404/1.4435 (316L) 1.4301/1.4404 (304/316L)
Measuring system
Sensor: Piezoresistive Thin film
Sensor filling: Synthetic oil, free of silicone FD1, FDA listed without
Measuring ranges / overload limits
Measuring range / overload limit: See order details
Vakuum tightness: Long term vacuum measurements at relative measurement ranges can alter the device characteristics.
(piezoresistive measuring system, only)
Zero settings
Zero point: Easy zero setting max. ± 20 %.
Accuracy
Limit point setting: per DIN 16086
Accuracy (Lin./Hyst./Repr.): 0.2 % v. of mr (mr ≥ 250 mbar)
0.5 mbar (mr < 250 mbar)
Long-term drift: ≤ 0.1 % / year per EN 61298-1
Temperature influence: Range: 0…50 °C:
≤ 0.25 % of mr (mr ≥ 400 mbar)
≤ 0.4 % of mr (mr < 400 mbar)
≤ 0.5 % of mr (mr < 160 mbar)
  Range: -20…0 and 50…85 °C:
≤ 0.4 % of mr (mr ≥ 400 mbar)
≤ 0.6 % of mr (mr < 400 mbar)
≤ 0.8 % of mr (mr < 160 mbar)
  (mr = measuring range)
Indication
Type: 4 digit, red LED with 7 segments
Digit high: 8.5 mm
Resolution: -9999…9999 digit
Accuracy: ± 0,2 % ± 1 digit
Temperatureinfluence: ± 0,1 %/10K
Alignment: Can be rotated through 300°,
Can be mirror-imaged by 180° when installed upside down
Indication: Visual confirmation for operator when a button is pressed
Decimal point: Automatic setting depending on measuring range/unit, max. 3 decimal places
Or manual setting 0...3 decimal places
Measuring unit: bar, mbar, PSI, kPa, MPa, %, mA
Indication automatically changing from measurement value to measurement unit or indication of unit or value per keystroke.
Output
Signal: 4…20 mA , 2-wire technology
Sampling rate: 10 measurements / second
Current range: 3.8…20.8 mA
Resolution: 2 μA
Current limitation: ≤ 22 mA
Alarm state: < 3.6 mA
Load, RB: RB ≤ (UV-14V)/0.022A [Ohm]
(UV = supply voltage)
Switching output (option)
Type: 2 floating contacts with common ground (low side NPN) or common power supply (high side PNP)
Switching capacity: 200 mA, short-circuit-proof
Optional 1 A
Switching status: breakers or makers, programmable, device off circuit: open contact
Switching function: window / hysteresis, programmable
Setting range: within range limits
Hysteresis: within range limits
Switching delay: 0,0…999.9s
Repeat accuracy: 0.2 % of full-scale value
Temperature influence: ± 0.1 % / 10K
Galvanic isolation: between transmitter and outputs
Switching cycles: > 10 millions
Voltage drop: < 1 V (< 1.5 V, if current is > 100 mA)
Output state indicator: red LED per switching output
Paramerterisation: 3-key parameterisation
Supply voltage
Functional range: 14…30 V DC
Temperature ranges
Ambient: -20…85 °C
Media: -20…100 °C
Storage: -40…85 °C
Tests and certificates
See documents
Mounting information
Mounting position: At choice
Calibration position: Vertical
Paramerterisation
Parameterisation see operating instruction BA_060.
Type series
CS2100

Documents

Name
Description
EN
DE
  • D4-017-40

    Data Sheet

  • BA_060

    Operating Instruction

  • KE_035

    Declaration of Conformity

Productrequest

返回