Pressure transmitter COMPACT for diaphragm seal operation, robust

Type series CC6010-C

  • EX
  • SIL2
Pressure transmitter COMPACT for diaphragm seal operation, robust - CC6010-C

Features

  • Measuring ranges 0...250 mbar up to 0...400 bar
  • Linearity error including hysteresis <+ 0.2 % f.s.
  • Piezoresistive measuring system
  • Separating foil from stainless steel or special materials
  • Completely encapsulated electronics
  • Stainless steel case as standard or field housing
  • Degree of protection IP 65, IP 67 option
  • Variuous output signals
  • Process temperature up to 200 °C

Options

  • Explosion protection for gases
  • Classification per SIL2
  • Inspection certificate material certificat as per DIN EN 10204-3.1

Technical Data

Constructional design / case
Design: - fiel housing IP 65 or IP 67, with cable gland
- right-angle plug per DIN EN 175301-803-A (DIN 43650 Form A), IP 65
- cable connection, IP 67
- circular connector M12, IP 65
  case material stainless steel
  union nut: polyamide (with plug connector or cable connection for electr. connection)
electronics encapsulated with silicone.
  Inner chamber aeration for measuring ranges < 16 bar over case thread or connection cable (depending on design)
Process connection: see order code for variants
material-Nr.: 1.4404 (316L) for the sleeves
Temperature ranges: - ambient temperature range: -25...+70 °C
- storage temperature range: -10...+90 °C
process temperature: see order details
Measuring ranges/overrange limits: see order details
intermediate measuring ranges upon request
Response time: ≤ 20 ms
Measuring accuracy: see data sheet
Auxiliary energy supply: standard design:
- nominal voltage 24 V DC
- function range 6...30 V DC
- max. allowable operating voltage 30 V DC
Supply voltage influenc: ≤ 0.01 % f.s. / V
Output signal: 4...20 mA, 2-wire technology
0...20 mA, 3-wire technology
4...20 mA, 3-wire technology
0...10 V, 3-wire technology
Current limitation in output signal: max. output current approx. 30 mA
Adjusting range: approx. ± 5 % f.s.; zero point and measuring span separately adjustable
Burden: 2-wire circuitry standard design Ra = UB-6V / 20 mA (KOhm)
UB = operating voltage
Ra = max. permissible burden resistance (incl. lead)
Functional safety: EN 61508, classificatio per SIL 2,TÜV-Reg.-No. 44 799 13190204
Burden influenc: or 500 ohm burden change: ≤ 0.1 % f.s.
Weights (without diaphragm seal): - fiel housing: approx. 460 g
- case with connector: approx. 200 g
Installation position: any
EMC test: - noise immunity according to EN 50082 section 2, version March 1995 issue for industry
- emitted interference according to EN 50081section 1, 1993 issue for residential and industrial areas
  Device emits no radiation of its own
Tests and certificates
See documents
Type series
CC6010-C, CC6011-C, CC6020-C, CC6021-C

Documents

Name
Description
EN
DE
  • D4-020-7

    Data Sheet

  • BA_005

    Operating Instruction

  • XA_006

    Ex Instructions

  • ZER_004

    Certificate - ATEX

  • ZER_049

    Certificate - SIL2

  • HE_084

    Manufacturer Declaration - SIL2

  • KE_022

    Declaration of Conformity

Productrequest