Differential pressure transmitter PASCAL Ci4 Delta P, highly overload protected, operating software LAB4Level

Type series CI4350

  • EX
Differential pressure transmitter PASCAL Ci4 Delta P, highly overload protected, operating software LAB4Level - CI4350

Features

  • Differential pressure transmitter with diaphragm seal
  • Simultaneous display of differential pressure and static pressure
  • Reference accuracy 0.07 %
  • Long-term stability 0,1 % within 5 years
  • Nominal ranges 100 mbar to 16 bar
  • Turndown up to 100:1
  • Stainless steel case in sturdy design, degree of protection IP 65/67
  • High-resolution display with intuitive 4-button operation and backlight
  • Comprehensive parameterising functions
  • Comprehensive simulation and diagnostic functions
  • Quick access to device data
  • Development according to SIL2
  • Maximum working pressure 160 bar
  • Measuring rate up to 50 Hz
  • Output signal 4…20 mA with HART® protocol
  • Media temperature -90…400 °C
  • Configuration memory
  • Digital communication via PDM, FDT/DTM, 375/475 Field Communicator
  • Output functions: linear, invers, square root, table function with up to 64 support points
  • Wetted parts stainless steel
  • EAC declaration (upon request)

Options

  • Explosion protection for gases and dust
  • Classification per SIL2 (in preparation)
  • Certificate of measuring equipment for Russian Federation
  • Material certificate per EN 10204
  • Calibration certificate per EN 10204
  • Operating software LAB4Level for intuitive parameterisation of level measurements
  • Removable display and control unit
  • Degree of protection IP 69K
  • Maximum working pressure 400 bar (upon request)

Technical Data

Measuring ranges
See data sheet
Constructional design / case
Ausführung: Two-chamber case, continously rotatable by ± 170°
Case surface blasted
Material case: - Stainless steel mat.no. 1.4301/1.4305 (304/303)
- Stainless steel mat.no. 1.4404 (316L)
Material front cover: - Stainless steel mat.no. 1.4305 (303)
- Stainless steel mat.no. 1.4404 (316L)
- Polypropylene, black
Gaskets: Silikon / NBR
Degree of protection per EN 60529: - IP 65 / IP 67
- IP 69K
Climatic category per EN 60721 3-4: 4K4H
Vibration resistance per EN 61298-3: 10…60 Hz: ± 0.35 mm
60…1000 Hz: 5 g
Material window: - Macrolon
- Non-splintering glass (requires front cover of stainless steel)
Elec. connection: - Circular connector M12
- Cable gland M16x1.5, PA black
- Cable gland M16x1.5, stainless steel
- Cable gland M20x1.5, PA black
- Cable gland M20x1.5, stainless steel
- 1/2" NPT, PA black
  Further connections upon request
Terminal blocks: - FSpring clamp terminals up to 1.5 mm2
- Pole terminals up to 2.5 mm2
- Screw terminals up to 2.5 mm2
Weight: approx. 2.9 kg
Type plate: Laser marking
Process connection plus-sided
Design: - Diaphragm seal direct with distance tube
- Diaphragm seal with stainless steel capillary and stainless steel protective tube
Design of diaphragm seals see order code.
Process connection minus-sided
Design: Process flange with connection dimension per EN 61518 and with mounting thread 7/16 – 20 UNF
- Process connection 1/4 – 18 NPT
- Process connection 1/2 – 14 NPT via oval flange (see accessories)
  Material: Stainless steel mat.-no. 1.4404 (316L)
  Ventilation:
- without ventilation, with sealing plug 1/4" NPT
- with ventilation valve 1/4" NPT
  Gasket:
- EPDM, FDA compliant (standard) temperature range -40...85 °C
- FKM (Viton) temperature range -20...85 °C
  Diaphragm material: Stainless steel mat.-no. 1.4404 (316L)
  Further connections and materials upon request.
Design: Diaphragm seal with stainless steel capillary and stainless steel protective tube
  Design of diaphragm seals see order code.
Material wetted parts
- Stainless steel mat.-no. 1.4404/1.4435 (316L)
- Hastelloy C276
- Tantal
- PTFE coating, vacuum-resistant
Further materials upon request.
Measuring system
Sensor: Piezoresistive measuring element
System filling: - Silicone oil
- Halocarbon oil upon request
Pressure transmission fluids
- Synthetic oil, free of silicon
- High temperature oil
- Halocarbon oil
Accuracy
Reference cond. per EN 61298-1: TU = const. (15…25) °C
φ = const. (45...75) % r.F.
pU = const. (860...1060) mbar
UB = 24 V DC (± 3 V DC)
RB = 50 Ω, HART: 250 Ω
Ground connected
Lower range value = 0 bar
Calibration position: Diaphragm seal on same height
Reference accuracy: See data sheet
Long-term drift: Refer to nominal range ≤ 0.1 % within 5 years
Temperature influence of ambient temperature: See data sheet
Temperature influence output (-40...80 °C): ≤ ±(0.04 % / 10 K)
Influence static pressure (per EN 61298-3): Refer to nominal range: ≤ ±(0.1 % + 0.1 % x TD)
Temperature influence diaphragm seal: Depends on design and profile of requirements.
  We provide a detailed error analysis upon request.
Indication
Display: - High-resolution graphic display with backlight
- 4-button operation
- Freely configurable display modes
- continuously rotatable by ± 170 (detent every 90°)
- Optional: Remote display and control unit, can be used up to 10 m away from measuring point
Configuration memory: All parameterisation data can be copied from the device into the configuration memory in the display module. The data is permanently stored there, even in the event of power failure.
  The parameters can be transferred simply and quickly to other devices.
Output
Signal: 2-wire technology 4…20 mA
Lower limit 3.8…4 mA
Upper limit 20…21 mA
Lower alarm current < 3.6 mA
Upper alarm current > 21 mA
Current limitation 22 mA
Operational availability < 12 s
Response time t90 at current output: typically 200 ms
Digitale communication: HART®-protocol, version 7
  Communication via:
- Siemens PDM
- Pactware or compatible systems (FDT/DTM)
- 375 / 475 Field Communicator
Funktion: - linear
- inverse response
- by square root
- table function with up to 64 support points
Turndown: max. 100:1
Damping: 0…999.9 s selectable in steps of 0.1 s
Measuring rate: 50 Hz
Resolution: 0,5 µA
Current sensing func.: 3.55…21.5 mA selectable in steps of 0.001 mA
Load R: R ≤ (UV-12V DC)/0.022 A [Ω]
U = Versorgungsspannung
  for HART communication: R ≥ 230 Ω
Supply voltage
Functional range: 12…30 V DC, protected against polarity reversal
Ripple: < 5 %
Temperature ranges
Ambient: -40…80 °C
(Display visibility is limited at temperatures below - 30 °C)
Measuring cell: -40...85 °C
Media: -90…400 °C
The temperature range of the pressure transmission fluid has to be observed.
Storage: -40…80 °C
Tests and certificates
See documents.
Type series
CI4350

Documents

Name
Description
EN
DE
  • D4-071-4

    Data Sheet

  • BA_072

    Operating Instruction - PASCAL Ci4

  • BA_078

    Operating Instruction - PASCAL Ci4 LEVEL

  • XA_022

    Ex Instructions

  • SA_001

    SIL Instructions

  • ZER_090

    Certificate - ATEX

  • ZER_091

    Certificate - IECEx

  • KE_042

    Declaration of Conformity

  • Software

    PASCAL Ci4 HART (DD/EDD) for Simatic PDM V6.0 SP5, V8.1 und V9.x

  • Software

    PASCAL Ci4 HART (DTM) for Pactware

  • Software

    PASCAL Ci4 LEVEL (DD/EDD) for Simatic PDM V9.x

  • Software

    PASCAL Ci4 HART (DD/EDD) for Simatic PDM V9.x

  • Software

    PASCAL Ci4 LEVEL (DD/EDD) for Emerson Handheld Communicator 375 / 475

  • Software

    PASCAL Ci4 HART (DD/EDD) for Emerson Handheld Communicator 375 / 475

Productrequest

返回