Parameterisation, simulation and adjustment Parameterisation Standard device Values 16 digits, freely selectable at any value within nominal range at any value within nominal range 0.0…999.9 s Device with operating software LAB4Level Values Default setting LABOM PASCAL Ci4 0 bar end of nominal range mbar, bar, Pa, hPa, kPa, MPa, g/cm2, kg/cm2, psi, atm, torr, mmH2O, mH2O, inH2O, ftH2O, mmHg, inHg mbar, bar, Pa, hPa, kPa, MPa, g/cm2, kg/cm2, psi, atm, torr, mmH2O, mH2O, inH2O, ftH2O, mmHg, inHg 0.0 s bar bar m l kg mm, cm, m, ft, in, yd l, hl, m3, in3, ft3, gal g, kg, t, lb g/cm3, kg/cm3, t/m3, kg/l, lb/in3, lb/ft3 g/cm3 Parameter device ID lower range value upper range value damping Display and control unit pressure unit static pressure unit 1 filling height unit volume unit weight unit (mass) density unit temperature unit lighting language °C, °F, °R, K on, off English, German English, Chinese English, Spanish, French English, Polish, German English, Turkish, German decimal point display mode (∆ p) auto, x.xxxx, xx.xxx, xxx.xx, xxxx.x, xxxxx five values, four values, three values, two values, big display display mode (level) level 4 values, level 2 values, five values, four values, three values, two values, big display main value (∆ p) main value (level) secondary values (∆ p) secondary values (Level) pressure (∆ p), current in %, current in mA filling height, volume, weight, pressure (∆ p), current in %, current in mA pressure (∆ p), static pressure, current in %, current in mA, sensor temperature, device ID, HART-TAG, HART-Descriptor, <leer> filling height, volumen, weight, pressure (∆ p), static pressure, current in %, current in mA, sensor temperature, density, device ID, HART-TAG, HART-Descriptor, <leer> level density offset height tank shape table Table function (∆ p) Table funktion (level) Current output measured value (∆ p) measured value (level) output function (∆ p) output function (level) lower current limit upper current limit alarm current position correction (mounting position) Maintenance counter maintenance interval status HART data HART address 64 support points (% from measuring range/current) pressure 0,1...20 g/cm3 max 99.999 m on, off 64 support points (filling height/volume) hight, volume, weight, pressure linear, invers, square root, table function linear, tank function 3.8…4.0 mA 20…21 mA low (<3.6 mA), high (> 21.0 mA) on, off 0…9999 days on, off 0…63 number of response preambels 5…20 current mode proportional, constant 1The static pressure will be displayed as absolute pressure by default, adjusted to 0 bar abs. °C on German as ordered as ordered as ordered as ordered auto 4 value level 4 value pressure filling height current in %, current in mA, device ID current in %, current in mA, device ID 1 g/cm3 0 m off pressure height linear linear 3.8 mA 2.5 mA low (<3.6 mA) off 0 days off 0 5 proportional DB_D4-071-4_en_11.00 2023-02 Differential pressure and level transmitter Page 5/17