Resistance thermometer MiniTherm, fast response

Type series GA2700 HY

  • EX
  • SIL2
  • EHEDG
Resistance thermometer MiniTherm, fast response - GA2700 HY

Features

  • Resistance thermometer for invasive temperature measurement in tanks and pipes
  • Pt100 directly integrated into a thermowell
  • Compact design
  • High measurement accuracy
  • Fast response
  • Process connections for food/pharmaceuticals/biotechnology
  • Connections per DIN 11851, VARIVENT® and Clamp per DIN 32676 / ISO 2852 with EHEDG certificate
  • Measuring resistor Pt100, class A
  • Circular connector M12

Options

  • Explosion protection
  • Classification per SIL2
  • Material certificate per EN 10204-3.1
  • Calibration certificate per EN 10204-3.1
  • Output signal 4...20 mA via transmitter PA2430
  • Output signal IO-Link V1.1 via transmitter PA2530
  • Thermowell with reduced tip Ø 4 mm
  • Wetted parts electropolished

Technical Data

Constructional design
Design: Pt100 directly integrated into a thermowell, various types of process connections are available
El. connection: Circular connector M12
Further electrical connections upon request.
Working pressure: max. 16 bar
(excluded VARIVENT®, Form N with max. 10 bar)
Measuring insert
Design: Thermowell Ø 6 mm
Option: Thermowell with reduced tip Ø 4 mm
Length see order code.
Measuring resistor: - Pt100 per EN 60751, class A 3-wire
- Pt100 per EN 60751, class A 4-wire (3-wire bridged)
Degree of protection per EN 60529: IP 67
Outpu signal transmitter
Output signal 4...20 mA : Detailed informations about transmitter type PA2430 see product page on www.labom.com.
Output signal IO-Link V1.1: Detailed informations about transmitter type PA2430 see product page on www.labom.com.
Process connection
Design: See order code
Sealing are not included in the scope of delivery.
Material wetted parts
Material: Stainless steel mat.-no. 1.4404 (316L)
Hygienic design
The surface roughness of the wetted parts made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3.
In case of choosing the additional feature HY, we guarantee the following surface roughness values:
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm
Further versions of hygienic design upon request.
Accuracy
Pt100: Per EN 60751, class A
Response time: Per EN 60751, test procedure with flowing water (without transmitter)
Thermowell Ø 6 mm: T90 = 5.5 s
Thermowell with reduced tip Ø 4 mm: T90 = 4.5 s
Temperature ranges
Ambient:1 -40…85 °C
Media: -50…200 °C
Storage:1 -40…85 °C
1 Different temperature ranges for devices with transmitter (see data sheets for the types PA2430 or PA2530).
Transmitter
Installation variants: - Transmitter, Type PA 2430, for circular connector M12
- Transmitter, Type PA 2530 IO-Link, for circular connector M12
- Transmitter head mounted, Type se-ries PA210., 4…20 mA, programmable
- Transmitter head mounted, Type se-ries PA220., electrically isolated, classification per SIL 2
- Transmitter head mounted, Type se-ries PA230., electrically isolated, classification per SIL 2, HART
Tests and certificates
See documents
Type series
GA2700HY, GA2701HY

Documents

Name
Description
EN
DE
  • T4-015

    Data Sheet

  • BA_053

    Operating Instructions

  • XA_001

    Ex Instructions

  • ZER_023

    Certifikate - (ATEX)

  • ZER_034

    Certifikate - (EHEDG)

  • HE_087

    Manufacturer´s Declaration

  • KE_011

    Declaration of Conformity