Bimetal thermometer NS 100/160, various process connections

Type series FA2400

  • EX
Bimetal thermometer NS 100/160, various process connections - FA2400

Features

  • High quality case with bajonet ring NS 100/160, Degree of protection IP 66
  • Nominal ranges -40 °C…600 °C, other ranges from -110 °C...600 °C upon request
  • Case and wetted parts of stainless steel
  • Different connections can be supplied
  • Accuracy class 1 as per EN 13190
  • Adjusting pointer for indication correction
  • EAC declaration (upon request)

Options

  • Explosion protection (ATEX) for mechanical devices
  • Certificate of measuring equipment for Russian Federation
  • Calibration certificate per EN 10204
  • Case with liquid filling
  • Connection to zone 0 with thermowells (upon request)

Technical Data

Constructional design / case
Design: High quality case with bajonet ring,
material: stainless steel mat.-no. 1.4301 (304)
Nominal size: NS 100 or NS 160
Degree of protection per EN 60529: IP 66
Filling: For damping the whole measuring system.
Depending on measuring range: Labofin (from -40 °C...100 °C) or silicone oil (from -110 °C...250 °C)
Case seal: Material gasket: NBR
Window: Non-splintering laminated glass.
Option: Non-splintering plastic (Macrolon)
Pointer shaft: Stainless steel mat.-no. 1.4571 (316Ti), with plastic bearing
With highly flexible joint helix for thermometers with adjustable angel stem
Scale: Pure aluminium, white with black inscription
Pointer: Pure aluminium, black
with adjustment for zero point correction
Weights: Bottom connection:
NS 100 without filling: approx. 0.4 kg
NS 100 with filling: approx. 0.6 kg
NS 160 without filling: approx. 0.8 kg
NS 160 with filling: approx. 1.5 kg
  Centre back connection:
NS 100 without filling: approx. 0.4 kg
NS 100 with filling: approx. 0.5 kg
NS 160 without filling: approx. 0.8 kg
NS 160 with filling: approx. 0.9 kg
  Adjustable angel stem:
NS 100 without filling: approx. 0.6 kg
NS 100 with filling: approx. 0.7 kg
NS 160 without filling: approx. 0.9 kg
NS 160 with filling: approx. 1.0 kg
Process connection
Design: - rigid temperature detecting element, bottom connection
- rigid temperature detecting element, centre back connection
- rigid temperature detecting element, adjustable angle stem (90°)
  Various process connections can be supplied (see order details).
Measuring element
Measuring element: Helix from thermostatic bimetal per DIN 1715, with good adjusting force and fast acting, thermally aged. Base and connecting piece laser welded.
Temperature sensor
Temperature-detecting element: Diameter 6 or 8 mm, standard lengths available.
  See order details, further sizes upon request.
  Material: stainless steel mat.-no. 1.4571 (316 Ti)
Nominal range
Nominal range (EN 13190): -40 °C…500 °C
(with restrictions also 600 °C), see order details.
  Further nominal ranges from -110 °C up to 600 °C (no normal range) upon request.
Accuracy
Accuracy class: 1.0 per EN 13190
  For devices with adjustable angle stem: The accuracy class does not take into account a possible error, which can be caused by altering the position of the joint. However, this possible error can be compensated for re-adjusting with the adjustable pointer.
Temperature ranges
Ambient: Per EN 13190.
Ambient temperatures that deviate from EN are to be specified.
Storage and transport: -20…60 °C
Further temperature ranges upon request.
Tests and Certificates
See documents
Instructions for use
The loading capacity of the temperature detecting element depends on the following parameters:
- Media
- Media pressure
- Media temperature
- Flow velocity
- Insertion length
- Material
A technical examination might be necessary as well as the use of a separate thermowell (Product group D5).
Information on other models see order details or upon request.
Further information to mounting and operation see Operating Instruction BA_017.
Type series
FA2400, FA3400, FA2600, FA3600, FA2300, FA3300, FA2500, FA3500, FA2310, FA3310, FA2510, FA3510

Documents

Name
Description
EN
DE
  • T2-025-1

    Data Sheet

  • BA_017

    Operating Instruction

  • XA_005

    Ex Instructions

  • KE_040

    Declaration of Conformity

Productrequest