Pressure transmitter/ switch PASCAL CS for diaphragm seal operation, hygienic

Type series CS2110

  • EHEDG
Pressure transmitter/ switch PASCAL CS for diaphragm seal operation, hygienic - CS2110

Features

  • Multifunctional pressure transmitter/pressure switch
  • Hygienic case with no notches or indentations
  • Degree of protection IP 65
  • 4 digit LED display, can be mirror-imaged by 180°
  • Indication module rotatable by 300°
  • Measuring ranges: 0…100 mbar up to 0…40 bar rel.,0…1 bar up to 0…6 bar abs.
  • Output signal 4...20 mA, 2-wire technology
  • Accuracy ≤ 0,2 %
  • Easy to program locally (as per VDM standard)
  • Galvanic isolation between transmitter and switching outputs
  • Various process connections with flush mounted diaphragm, selected connections with EHEDG certificate

Options

  • Certificate of measuring equipment for Russian Federation
  • Material certificate as per EN 10204-3.1
  • Calibration certificate as per EN 10204-3.1
  • Roughness height rating with inspection certificate acc. to DIN EN 10204-3.1
  • 2 floating contacts
  • Switching contacts with high switching current (1A)
  • Wetted parts electropolished
  • Electrical connection rotatable by 300°
  • Degree of protection IP 67
  • Hygienic design
  • EAC declaration (upon request)

Technical Data

Constructional design / case
Design: Hygienic case design, including gasket forseamless design
Fully encapsulated electronics unit
Material: Stainless steel mat.-no. 1.4301 (304)
Indication module: macrolon
Degree of protection: - IP 65 per EN 60529
- Optional IP 67 per EN 60529
Pressure compensation: Aeration via sintered filter
Electrical connection: - circular connector M12, 4 pin
- circular connector M12, 8 pin (necessary for devices with switching contacts)
  Incl. sealing ring to ensure case is completely sealed
Climatic category: DIN EN 60721 3-4, 4K4H
Process connection
Design: See order details
Hygienic design
The surface roughness of the wetted parts made of stain-less steel are executed according to EHEDG Doc.8 and ASME BPE SF3.
In case of choosing the additional feature HY, we guarantee the following surface roughness values:
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm
Further versions of hygienic design upon request.
Measuring system
Sensor: Piezoresistive measuring element
System filling: Synthetic oil, free of silicon FD1, FDA listed, class USDA-H1
Measuring ranges / overload limits
Measuring range / overload limit: See order details
Vakuum tightness: Long term vacuum measurements at relative measurement ranges can alter the device characteristics.
(piezoresistive measuring system, only)
Zero settings
Zero point: Easy zero setting max. ± 20 %.
Accuracy
Limit point setting: per DIN 16086
Accuracy (Lin./Hyst./Repr.): 0.2 % v. of mr (mr ≥ 250 mbar)
0.5 mbar (mr < 250 mbar)
Long-term drift: ≤ 0.1 % / year per EN 61298-1
Temperature influence: Range: 0…50 °C:
≤ 0.25 % of mr (mr ≥ 400 mbar)
≤ 0.4 % of mr (mr < 400 mbar)
≤ 0.5 % of mr (mr < 160 mbar)
  Range: -20…0 and 50…85 °C:
≤ 0.4 % of mr (mr ≥ 400 mbar)
≤ 0.6 % of mr (mr < 400 mbar)
≤ 0.8 % of mr (mr < 160 mbar)
  (mr = measuring range)
  Process connection:
(zero error)
DN 25/1“: 4.8 mbar/10K,
DN 32/1 1/2“: 2.3 mbar/10K,
DN 40: 1.6 mbar/10K,
DN 50/2“: 0.6 mbar/10K
Indication
Type: 4 digit, red LED with 7 segments
Digit high: 8.5 mm
Resolution: -9999…9999 digit
Accuracy: ± 0,2 % ± 1 digit
Temperatureinfluence: ± 0,1 %/10K
Alignment: Can be rotated through 300°,
Can be mirror-imaged by 180° when installed upside down
Indication: Visual confirmation for operator when a button is pressed
Decimal point: Automatic setting depending on measuring range/unit, max. 3 decimal places
Or manual setting 0...3 decimal places
Measuring unit: bar, mbar, PSI, kPa, MPa, %, mA
Indication automatically changing from measurement value to measurement unit or indication of unit or value per keystroke.
Output
Signal: 4…20 mA , 2-wire technology
Sampling rate: 10 measurements / second
Current range: 3.8…20.8 mA
Resolution: 2 μA
Current limitation: ≤ 22 mA
Alarm state: < 3.6 mA
Load, RB: RB ≤ (UV-14V)/0.022A [Ohm]
(UV = supply voltage)
Switching output (option)
Type: 2 floating contacts with common ground (low side NPN) or common power supply (high side PNP)
Switching capacity: 200 mA, short-circuit-proof
Optional 1 A
Switching status: breakers or makers, programmable, device off circuit: open contact
Switching function: window / hysteresis, programmable
Setting range: within range limits
Hysteresis: within range limits
Switching delay: 0,0…999.9s
Repeat accuracy: 0.2 % of full-scale value
Temperature influence: ± 0.1 % / 10K
Galvanic isolation: between transmitter and outputs
Switching cycles: > 10 millions
Voltage drop: < 1 V (< 1.5 V, if current is > 100 mA)
Output state indicator: red LED per switching output
Paramerterisation: 3-key parameterisation
Supply voltage
Functional range: 14…30 V DC
Temperature ranges
Ambient: -20…85 °C
Medium: -20…125° C, short term 140 °C, optional up to 160 °C for 1 h.
Higher process temperatures upon request
Storage: -40…85 °C
Tests and certificates
See documents
Mounting information
Mounting position: At choice
Calibration position: Vertical
Type series
CS2110

Documents

Name
Description
EN
DE
  • D4-017-42

    Data Sheet

  • BA_060

    Operating Instruction

  • KE_035

    Declaration of Conformity

Productrequest

Go back