Pressure transmitter COMPACT for diaphragm seal operation, hygienic

Type series CC6010-F

  • EX
  • SIL2
  • EHEDG
Pressure transmitter COMPACT for diaphragm seal operation, hygienic - CC6010-F

Features

  • Measuring ranges 0...250 mbar up to 0...100 bar
  • Linearity error including hysteresis <+ 0.2 % f.s.
  • Piezoresistive measuring system
  • Hygienic design according to EHEDG, FDA und GMP recommendations
  • Material and surface quality according to the hygienic requirements
  • Wetted parts of stainless steel; completely welded
  • Stainless steel case as standard or field housing
  • Degree of protection IP 65, IP 67 option
  • Various output signals
  • Process temperature up to 200 °C

Options

  • Explosion protection for gases
  • Classification per SIL2
  • Inspection certificate material certificat as per DIN EN 10204-3.1

Technical Data

Constructional design / case
Case design: - fiel housing IP 65 or IP 67, with cable gland
  - right-angle plug per EN 175301-803-A (DIN 43650 Form A), IP 65
  - cable connection, IP 67
  - circular connector M12, IP 65
  case material stainless steel union nut: polyamide (with plug connector or cable connection for electr. connection)electronics encapsulated with silicone.
  Inner chamber aeration for measuring ranges < 16 bar over case thread or connection cable (depending on design)
Process connection: see next page or order code for variantsmaterial-Nr.: 1.4404 (316L) for the sleeves
Temperature ranges: ambient temperature range: -25...+70 °C
storage temperature range: -10...+90 °C
process temperature: see order details
Measuring ranges/overrange limits: see order details
intermediate measuring ranges upon request
Response time: ≤ 20 ms
Measuring accuracy: see data sheet
Auxiliary energy supply: standard design:·
- nominal voltage 24 V DC
- function range 6...30 V DC
- max allowable operating voltage 30 V DC
Supply voltage influence: ≤ 0,01 % v.E./V
Output signal: 4...20 mA, 2-wire technology
0...20 mA, 3-wire technology
4...20 mA, 3-wire technology
0...10 V, 3-wire technology
Current limitation in output signal: max. output current approx. 30 mA
Adjusting range: approx. ± 5 % f.s., zero point and measuring span separately adjustable
Burden: standard design Ra= UB-6V / 20 mA (KOhm)
UB= operating voltage
Ra= max. permissible burden resistance (incl. lead)
Burden influenc: for 500 ohm burden change: ≤ 0,1 % v.E.
Functional safety: EN 61508, classificatio per SIL2, TÜV-Reg.-No.44 799 13190204
Weights (without diaphragm seal): - field housing: ca. 460 g
- case with connector: ca. 200 g
Installation position: any
EMC test: - noise immunity according to EN 50082 section 2, version March 1995 issue for industry
- emitted interference according to EN 50081 section 1, 1993 issue for residential and industrial areas
Device emits no radiation of its own
Tests and certificates
See documents
Type series
CC6010-F, CC6011-F, CC6020-F, CC6021-F

Documents

Name
Description
EN
DE
  • D4-020-7

    Data Sheet

  • BA_005

    Operating Instruction

  • XA_006

    Ex Instructions

  • ZER_004

    Certificate - ATEX

  • ZER_049

    Certificate - SIL2

  • HE_084

    Manufacturer Declaration - SIL2

  • KE_022

    Declaration of Conformity

Productrequest