Pressure transmitter UNIVERSAL CA with threaded connection

Type series CA2100

Pressure transmitter UNIVERSAL CA with threaded connection - CA2100

Features

  • Universal pressure transmitter
  • Stainless steel case, degree of protection IP 65
  • Direct ventilated sensor element
  • Measuring ranges: 0…100 mbar to 0…400 bar rel.; 0…1 bar to 0…6 bar abs.
  • Accuracy ≤ 0.2 %
  • Output signal 4...20 mA, 2-wire technology
  • Easy zero setting by using a magnet
  • Various process connections

Options

  • Certificate of measuring equipment for Russian Federation
  • Material certificate as per EN 10204-3.1
  • Calibration certificate as per EN 10204-3.1
  • Degree of protection IP 67
  • EAC declaration (upon request)

Technical Data

Constructional design / case
Design: Sturdy case design
  Excellent moisture protection
  Fully encapsulated electronics unit
Material: Stainless steel mat.-no. 1.4301 (304)
Degree of protection: IP 65 per EN 60529
  Optional IP 67 per EN 60529
Pressure compensation: Aeration via sintered filter
El. connection: Circular connector M12x1
  Right angle plug EN 175301-803-A (DIN 43650 model A)
  others upon request
Climatic category: DIN EN 60721 3-4, 4K4H
Process connection
Design: See order details
Material wetted parts
Sensor: Piezoresistive Thin film
Sensor diaphragm: 1.4404/1.4435 (316L) 1.4542 (630)
Socket: 1.4404/1.4435 (316L) 1.4301/1.4404 (304/316L)
Measuring system
Sensor: Piezoresistive Thin film
Sensor filling: Synthetic oil, free of silicone FD1, FDA listed without
Measuring ranges / overload limits
Measuring ranges / overload limits: See order details
Vacuum tightness: Long term vacuum measurements at relative measurement ranges can alter the device characteristics.
(piezoresistive measuring system, only)
Zero settings
Zero point: Easy zero setting max. ± 20 %
Accuracy
Limit point setting: per DIN 16086
Accuracy (Lin./Hyst./Repr.): 0.2 % v. of mr (mr ≥ 250 mbar) 0.5 mbar (mr < 250 mbar)
Long-term drift: ≤ 0.1 % / year per EN 61298-1
Temperature influence: Range: 0…50 °C:
≤ 0.25 % of mr (mr ≥ 400 mbar)
≤ 0.4 % of mr (mr < 400 mbar)
≤ 0.5 % of mr (mr < 160 mbar)
  Range: -20…0 and 50…85 °C:
≤ 0.4 % of mr (mr ≥ 400 mbar)
≤ 0.6 % of mr (mr < 400 mbar)
≤ 0.8 % of mr (mr < 160 mbar)
  (mr = measuring range)
Output
Signal: 4…20 mA in 2-wire technology
Sampling rate: 10 measurement/second
Current range: 3.8…20.8 mA
Resolution: 2 µA
Current limitation: ≤ 22 mA
Alarm state: < 3.6 mA
Load, RB: RB ≤ (UV-9V)/0.022A [Ohm]
  UV = supply voltage
Supply voltage
Function range: 9...30 V DC
Temperature ranges
Ambient: -20...85 °C
Media: -20...100 °C
Storage: -40...85 °C
Tests and certificates
See documents
Mounting information
Mounting position: At choice
Calibration position: Vertical
Type series
CA2110

Documents

Name
Description
EN
DE
  • D4-018-10

    Data Sheet

  • BA_059

    Operating Instruction

  • KE_035

    Declaration of Conformity

Productrequest