Constructional design / case
Design: | Compact case with outstanding protection against moisture |
Material: | Stainless steel mat.-no. 1.4301 (304) |
Degree of protection per EN 60529: | Circular connector: IP 65 / IP 67 Right-angle plug: IP 65 |
Pressure compensation: | Ventilation via electrical connection |
Electrical connection: | Circular connector M12x1 (4 pin) |
Right-angle plug per DIN EN 175 301803-A (DIN 43650 model A) | |
Weight: | Approx. 0.15 kg |
Process connection
Design: | For measuring range up to 1000 bar: - G 1/2 B per EN 837-1 - G 1/4 A per DIN EN ISO 1179-2 (DIN 3852-11) model E |
For measuring range up to 600 bar: - G 1/4 B per EN 837-1 - G 1/2 A per DIN EN ISO 1179-2 (DIN 3852-11) model E - 1/4“ NPT per EN 837-1 - 1/2“ NPT per EN 837-1 - M20 x 1.5 |
Material wetted parts
Process connection: | Stainless steel mat.-no. 1.4301 (304), 1.4542 (630) at nominal range 1000 bar |
Diaphragm: | Stainless steel mat.-no. 1.4542 (630) |
Measuring system
Sensor: | Thin film sensor |
Nominal range
For detailed information see data sheet. |
Accuracy
Limit point setting: | per DIN 16086 |
Reference conditions: | per DIN EN 60770-1 |
Calibration position: | vertical mounting position |
Accuracy (Lin./Hyst./Rep.): | ≤ 0.5 % of nominal range |
optional: ≤ 0.3 % of nominal range | |
Long term drift: | ≤ 0.1 % / year of nominal range |
Temperature-influence (trans-mitter): | ≤ 0.2 %/10 K of nominal range |
Output
Signal: | 4…20 mA (20…4 mA), 2-wire technology |
Damping: | 12 ms |
Measuring rate: | 80 Hz * |
Current range: | 3.7...22 mA |
Resolution: | 6 µA |
Load, RB: | RB ≤ (UV-10V)/0,022 A [Ω] (UV = supply voltage) |
* Other measuring rates upon request.
Supply voltage
Functional range: | 10...32 V DC |
Temperature ranges
Ambient: | -40...85 °C |
Media: | -40...120 °C (at a maximal ambient temperature of 40 °C) |
Storage: | -40...85 °C |
Extended temperature ranges upon request
Tests and certificates
EMC: directives 2004/108/EG |
- Certificate of measuring equipment for Russian Federation |