Pressure transmitter COMPACT ECOnomic with threaded connection

Type series CA1100

Pressure transmitter COMPACT ECOnomic with threaded connection - CA1100

Features

  • Digital pressure transmitter
  • Case and wetted parts of stainless steel, degree of protection IP 65 / IP 67
  • Measuring ranges: 0…1 bar up to 0…1000 bar; -1…0 bar up to -1…15 bar
  • Output signal 4…20 mA, 2-wire technology
  • Accuracy ≤ 0.5 %
  • Easy zero point correction using a magnet
  • Media temperature -40…120 °C
  • EAC declaration (upon request)

Options

  • Certificate of measuring equipment for Russian Federation
  • Output signal (invers) 20…4 mA
  • Various process connections
  • Further electrical connections
  • Accuracy ≤ 0.3 %

Technical Data

Constructional design / case
Design: Compact case with outstanding protection against moisture
Material: Stainless steel mat.-no. 1.4301 (304)
Degree of protection per EN 60529: Circular connector: IP 65 / IP 67
Right-angle plug: IP 65
Pressure compensation: Ventilation via electrical connection
Electrical connection: Circular connector M12x1 (4 pin)
  Right-angle plug per DIN EN 175 301803-A (DIN 43650 model A)
Weight: Approx. 0.15 kg
Process connection
Design: For measuring range up to 1000 bar:
- G 1/2 B per EN 837-1
- G 1/4 A per DIN EN ISO 1179-2 (DIN 3852-11) model E
  For measuring range up to 600 bar:
- G 1/4 B per EN 837-1
- G 1/2 A per DIN EN ISO 1179-2 (DIN 3852-11) model E
- 1/4“ NPT per EN 837-1
- 1/2“ NPT per EN 837-1
- M20 x 1.5
Material wetted parts
Process connection: Stainless steel mat.-no. 1.4301 (304), 1.4542 (630) at nominal range 1000 bar
Diaphragm: Stainless steel mat.-no. 1.4542 (630)
Measuring system
Sensor: Thin film sensor
Nominal range
For detailed information see data sheet.
Accuracy
Limit point setting: per DIN 16086
Reference conditions: per DIN EN 60770-1
Calibration position: vertical mounting position
Accuracy (Lin./Hyst./Rep.): ≤ 0.5 % of nominal range
  optional: ≤ 0.3 % of nominal range
Long term drift: ≤ 0.1 % / year of nominal range
Temperature-influence (trans-mitter): ≤ 0.2 %/10 K of nominal range
Output
Signal: 4…20 mA (20…4 mA), 2-wire technology
Damping: 12 ms
Measuring rate: 80 Hz *
Current range: 3.7...22 mA
Resolution: 6 µA
Load, RB: RB ≤ (UV-10V)/0,022 A [Ω]
(UV = supply voltage)
* Other measuring rates upon request.
Supply voltage
Functional range: 10...32 V DC
Temperature ranges
Ambient: -40...85 °C
Media: -40...120 °C
(at a maximal ambient temperature of 40 °C)
Storage: -40...85 °C
Extended temperature ranges upon request
Tests and certificates
EMC: directives 2004/108/EG
- Certificate of measuring equipment for Russian Federation

Documents

Name
Description
EN
DE
  • D4-019-4

    Data Sheet

  • BA_075

    Operating Instruction

  • XA_012

    Ex Instructions

  • ZER_094

    Certificate - ATEX

  • KE_044

    Declaration of Conformity

Productrequest