Submersible pressure transmitter for hydrost. level meas.

Type series CG2010

  • EX
Submersible pressure transmitter for hydrost. level meas. - CG2010

Features

  • Digital design of the electronic unit
  • Measuring ranges 0...160 mbar to 0...2500 mbar each intermediate value adjustable
  • Accuracy 0.15 %
  • Immersion case: stainless steel, coated
  • Titanium diaphragm
  • Cable connection pluggable
  • Degree of protection IP 68
  • Output signal: 4...20 mA

Options

  • Temperature measuring with Pt 100
  • Explosion protection: II 1G Ex ia IIC T6 Ga
  • Can be parameterized via PC (FSK-Bus)

Technical Data

Instrument ranges
Instrument ranges: see data sheet
Constructional design / case
Housing material: stainless steel, mat.-no. 1.4404 (316L), coated
Diaphragm material: titanium
Degree of protection: IP 68, immersible
Dlectrical connection: stainless steel connector, degree of protection IP 68
Cable connection: pluggable, slit cable 5 strand, see accessories, observe mounting instructions
Weights: probe: approx. 0.7 kg
Weights: + supply lines depending on length/m: approx 0.1 kg
Measuring system: sensor: piezoresistive measuring bridge, protected by an internal high-grade steel diaphragm
  system filling: silicon free, synthetic oil
Temperature ranges
Ambient temperature: -20...+85 °C
Storage temperature: -25...+85 °C
Note safety values as per examination certificate!
Supply
Function range: 12...30 V DC
Output
Pressure measurement: Signal: 4...20 mA, 2-wire circuitry
Current range: 3,8...20,8 mA
Current limitation: 22 mA
  Alarm state: < 3.6 mA standard, option: > 21 mA
Response time: 160 ms
Damping: 0...120 seconds, standard: 0.0 sec
Burden: R ≤ UB - 12 V /20 mA (kOhm)
Temperature measurment: Output signal: Pt 100, 2-wire circuitry
Application range: -20...+85 °C
Response time T90: approx. 10 min.
R ≥ 250 Ω via communication with LEVELcom
Accuracy
In general: Limit point setting:
Reference conditions:
Calibration position: vertical mounting position
per DIN 16086
per EN 60770-1
vertical mounting position
Pressure: see data sheet F2-050  
Temperature: Measuring element: Pt 100 class B, EN 60751
Tests and certificates
See documents
Parameterizing with LEVELcom
Parameterizing: see data sheet
Type series
CG2010, CG2011

Documents

Name
Description
EN
DE
  • F2-050

    Data sheet

  • BA_048

    Operating instruction

  • XA_008

    Ex Instructions

  • KE_024

    Declaration of Conformity

Productrequest