• Sie sind hier
  • Labom DE
  • Produkte
  • Druck
  • HYGIENIC Tubus Ø 76 mm with clamping flange, dead-zone free measuring

HYGIENIC Tubus Ø 76 mm with clamping flange, dead-zone free measuring

Typenreihe DL8120

  • EHEDG
HYGIENIC Tubus Ø 76 mm with clamping flange, dead-zone free measuring - DL8120

Merkmale

  • Flush-mounted separating diaphragm of stainless steel or special material
  • Alternative with reinforced diaphragm in LTC technology (reduced temperature influence)
  • Volume optimized diaphragm base
  • EHEDG-certified
  • Available with loose and fixed clamping flange
  • System fillings for different applications
  • Measuring device connection: directly welded, directly screwed, with temperature decoupler, with capillary

Optionen

  • Material certificate acc. to DIN EN 10204-3.1
  • Electropolishing (wetted parts)
  • Hygienic design with advanced surface quality
  • Special materials upon request

Technische Daten

Constructional design / case
Basic body: Volume reduced diaphragm base
Material: stainless steel mat.-no. 1.4404/1.4435 (316L), alternative Hastelloy C276
Clamping flange: Material: Stainless steel mat.-no. 1.4435 / 1.4404 (316L)
Diaphragm: Flush-mounted diaphragm, laser welded; alternative with reduced temperature influence and reinforced diaphragm in LTC technology.
(LTC=Low Temperature Coefficient)
  Further details see General technical information TA_031.
Material wetted parts: Diaphragm: Stainless steel mat.-no. 1.4435 (316L), alternative Hastelloy C276
Further materials upon request
  Basic body: Stainless steel mat.-no. 1.4404/1.4435 (316L), alternative Hastelloy C276
System filling
See order details; further fillings upon request.
Further details about pressure transmission fluids see general technical information TA_038.
Process connection
Design: HYGIENIC Tubus Ø 76 mm with
- loose clamping flange
- fixed clamping flange
Nominal pressure: PN 16
Gasket: Material EPDM, FDA listed
Temperature range: -45...150 °C
Measuring device connection
See order details.
Material stainless steel mat.-no. 1.4301 (304)
Hygienic design
The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3 (Code: HY).
We guarantee the following surface roughness values:
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm
Further versions of hygienic design upon request.
Temperature error
In order to optimise the system we provide a detailed error calculation upon request .
Weight
With measuring device connection G1/2 approx. 0.8 kg
Further information about diaphragm seals see general technical information TA_031.
Type series
DL8120, DL8130

Dokumente

Name
Beschreibung
DE
EN
  • D5-024-6

    Data Sheet

  • TA_031

    Technical Information - General Information

  • TA_038

    Technical Information - Pressure Transmission Fluids

Produktanfrage